3-14
3.5.4 Sweep Configuration
Sweepless
Sweep requires that the following parameters be setup:
•
Sweep Limit Variable. The Sweep Limit Variable is "X" in the
response flatness expression (n/10 + X) used during sweep
measurements to compare actual system response to the
formula. “X” is adjustable from 0.0 to 5.0 (default is 1.0).
•
Show Horizontal Markers. The horizontal markers
continuously track Max/Min values in the area of the graph
between the vertical markers.
•
Sweep File Overlay. Sweep file overlay enables you to view a
stored sweep response simultaneously with a "live" sweep
response for direct comparison. The sweep file overlay option
must be enabled for viewing both traces simultaneously. With
this option disabled, stored files are displayed for normal viewing
without the live response superimposed. If the sweep file
overlay option is enabled, the live response overlays the stored
response during viewing. Use the up/down arrow keys to enable
the option.
•
Include Audio Carriers. This selection allows the audio carriers
to be excluded, resulting in a faster sweep. Use the up/down
arrow keys to include (yes) or exclude (no) audio.
3.5.5 Configuring a Digital Carrier in a Channel Plan
Follow these instructions to set up digital channels in your channel
plan:
•
Turn the unit ON and press the NAV button, then
Config
.
•
From the menu, select
Channel Plan
•
Scroll to
Edit Channel Parameters,
and then press the
↵
Enter
button.
•
From the channel line-up, highlight the channel that you
are going to configure as digital, then press the
Edit
Channel icon, or
↵
Enter.
•
Highlight
the
Type
line in the
Parameters
box, then
↵
Enter.
•
Press the up/down arrow key until the type is
Digi
.
•
Highlight
the
Frequency (MHz)
line in the
Parameters
box.
•
Using the numeric keypad, type the
center frequency
of the
digital carrier, and then press the
↵
Enter button.