6-12
Scale
The scale parameter (1, 2, 5, & 10 dB/div) can be adjusted
only
with up/down arrow keys. For example, if the reference level is
set to 0 dB and the sale is set at 10 dB/div the horizontal grid line
at the center equals -30 dB
Trace Averaging
Soft key that enables and disables
Trace Averaging
. For use
when measuring power levels of TDMA (bursty) transmitters
such as cable modems. Useful when measuring D/U (Desired to
Undesired) signal quality.
Bandwidth
Press this to enter the Bandwidth sub-menu. The
Bandwidth
menu allows you to set the resolution bandwidth, video
bandwidth and carrier measurement bandwidth.
Resolution Bandwidth
Press to set
Resolution Bandwidth
: 30 kHz, 280 kHz or 2 MHz. A
value of 280 kHz is used as the nominal value. 30 kHz or 2 MHz
may be used when carrier spacing is very narrow or very wide
respectively.
Video Bandwidth
Press to set the
Video Bandwidth
: Auto, 100 kHz, 10 kHz, or 100
Hz. Auto should be used to prevent aliasing. You may want to
change to a low value when looking at carrier power.