110
Coding in the delivered condition
Possible change
F9:–14
Temperature limit for rais-
ing the reduced set room
temperature –14 °C; see
example on page 163
(only for weather-com-
pensated control units)
F9:+10
to
F9:–60
Temperature limit for rais-
ing the set room tempera-
ture to the value selected
for standard mode adjusta-
ble from
+10 to –60 °C
FA:20
Raising the set boiler wa-
ter or flow temperature by
20 % when changing
from operation with re-
duced room temperature
to operation with stand-
ard room temperature.
See example on
page 164 (only for
weather-compensated
control units)
FA:0
to
FA:50
Temperature rise adjusta-
ble from 0 to 50 %
Fb:60
Duration of the set boiler
water or flow temperature
rise (see coding address
"FA") 60 min. See exam-
ple on page 164 (only for
weather-compensated
control units)
Fb:0
to
Fb:300
Duration adjustable from 0
to 300 min
Code 2
"Heating circuit ..."/group 5
(cont.)
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...