126
Dis-
played
fault
code
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
bC
X
Control mode
without remote
control
Communica-
tion error, re-
mote control
Vitotrol heat-
ing circuit 1
(without mix-
er)
Check connec-
tions, cable, coding
address "A0" in
group
"Heating
circuit..."5
/ and re-
mote control con-
figuration (see
page 166).
For wireless re-
mote controls:
Check connec-
tions, place remote
control unit close to
the boiler
bd
X
Control mode
without remote
control
Communica-
tion error, re-
mote control
Vitotrol heat-
ing circuit 2
(with mixer)
Check connec-
tions, cable, coding
address "A0" in
group
"Heating
circuit..."
/
5
and re-
mote control con-
figuration (see
page 166).
For wireless re-
mote controls:
Check connec-
tions, place remote
control unit close to
the boiler
Troubleshooting
Fault codes
(cont.)
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...