![Viessmann Vitodens 222-F B2TA series Скачать руководство пользователя страница 188](http://html1.mh-extra.com/html/viessmann/vitodens-222-f-b2ta-series/vitodens-222-f-b2ta-series_installation-and-service-instructions-manual_1017277188.webp)
188
Rated voltage
230 V
Rated frequency
50 Hz
Rated current
6 A
Safety category
I
IP rating
IP X 4 D to
EN 60529
Permissible ambient temperature
■ During operation
0 to +40 °C
■ During storage and
transport
–20 to +65 °C
Electronic tempera-
ture limiter setting
81 °C
Temperature limiter
setting
100 °C (fixed)
Backup fuse (power
supply)
Max. 16 A
Rated heating output range
at T
V
/T
R
50/30 °C
kW
3.2 (4.8)
*2
-
13
3.2 (4.8)
*2
-
19
5.2 (8.8)
*2
-
26
5.2 (8.8)
*2
-
35
at T
V
/T
R
80/60 °C
kW
2.9 (4.3)
*2
-
11.8
2.9 (4.3)
*2
-
17.2
4.7 (8.0)
*2
-
23.7
4.7 (8.0)
*2
-
31.7
for DHW
heating
kW
2.9 (4.3)
*2
-
17.2
2.9 (4.3)
*2
-
17.2
4.7 (8.0)
*2
-
29.3
4.7 (8.0)
*2
-
33.5
Rated heat input range
kW
3.1 (4.5)
*2
-
17.9
3.1 (4.5)
*2
-
17.9
4.9 (8.3)
*2
-
30.5
4.9 (8.3)
*2
-
34.9
Power consumption
In the deliv-
ered condi-
tion
W
39
53
68
89
Maximum
W
102
105
154
166
Supply values
relative to the max. load
Natural gas E m
3
/h
1.89
1.89
3.23
3.69
Natural gas
LL
m
3
/h
2.20
2.20
3.75
4.30
LPG P
kg/h
1.40
1.40
2.38
2.73
Product ID
_
-0085CN0050
*2
Only when operating with LPG P
Specification
Specification
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...