![Viessmann Vitodens 222-F B2TA series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/viessmann/vitodens-222-f-b2ta-series/vitodens-222-f-b2ta-series_installation-and-service-instructions-manual_1017277002.webp)
2
Please follow these safety instructions closely to prevent accidents and mate-
rial losses.
Safety instructions explained
Danger
This symbol warns against the
risk of injury.
!
Please note
This symbol warns against the
risk of material losses and envi-
ronmental pollution.
Note
Details identified by the word "Note" con-
tain additional information.
Target group
These instructions are exclusively inten-
ded for qualified contractors.
■ Work on gas installations must only be
carried out by a registered gas fitter.
■ Work on electrical equipment must
only be carried out by a qualified elec-
trician.
■ The system must be commissioned by
the system installer or a qualified per-
son authorised by the installer.
Regulations
Observe the following when working on
this system:
■ Statutory regulations regarding the
prevention of accidents
■ Statutory regulations regarding envi-
ronmental protection
■ Codes of practice of the relevant trade
associations
■ All current safety regulations as
defined by DIN, EN, DVGW, TRGI,
TRF, VDE and all locally applicable
standards
a
ÖNORM, EN, ÖVGW-TR Gas,
ÖVGW-TRF and ÖVE
c
SEV, SUVA, SVGW, SVTI,
SWKI, VKF and EKAS guideline
1942: LPG, part 2
If you smell gas
Danger
Escaping gas can lead to explo-
sions which may result in serious
injury.
■ Do not smoke. Prevent naked
flames and sparks. Do not
switch lights or electrical appli-
ances on or off.
■ Close the gas shut-off valve.
■ Open windows and doors.
■ Evacuate any people from the
danger zone.
■ Notify your gas or electricity
supply utility from outside the
building.
■ Shut off the electricity supply to
the building from a safe place
(outside the building).
Safety instructions
Safety instructions
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...