Setting the time and date - only for weather-compensated control
units
The time and date need to be reset dur-
ing commissioning or after a prolonged
time out of use.
Extended menu:
1.
å
2.
"Settings"
3.
"Time/Date"
4. Set current time and date.
Note on automatic testing of the flue gas temperature sensor
Weather-compensated control unit
Constant temperature control unit
As soon as the time and date have been
set, the control unit automatically checks
the function of the flue gas temperature
sensor.
The display shows:
"Flue gas temp sen-
sor test"
and
"Active"
.
Note
If the flue gas temperature sensor is in-
correctly positioned, commissioning will
be cancelled and fault message A3
shown (see page 144).
Immediately after being switched on, the
control unit automatically checks the func-
tion of the flue gas temperature sensor.
The display shows:
"A"
.
Note
If the flue gas temperature sensor is in-
correctly positioned, commissioning will
be cancelled and fault message A3
shown (see page 144).
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...