21
Connections at plug 230 V~
fÖ
Power supply
lH
■ Power supply for accessories
■ External demand/blocking
■ Room temperature control unit
(remove jumper
B
when making
this connection):
– Vitotrol 100, type UTA
– Vitotrol 100, type UTDB
– Vitotrol 100, type UTDB-RF
Connections at LV plug
X3
Plug X3 can be removed to facili-
tate installation.
!
Outside temperature sensor
?
Flow temperature sensor for
low loss header (accessories)
A
Radio clock receiver
X4
KM BUS connection, variable
speed heating circuit pump (if
installed)
aVG
KM BUS subscriber (accessories)
To connect several accessories,
see page 25.
■ Vitotrol 200A or 300A remote
control
■ Vitocom 100, type GSM
■ Extension kit for one heating cir-
cuit with mixer
■ Extension AM1
■ Extension EA1
■ Wireless base station
■ KM BUS distributor
Information on connecting
accessories
When connecting accessories
observe the separate installation
instructions provided with them.
Outside temperature sensor
!
For fitting the wireless outside tempera-
ture sensor (wireless accessory):
Wireless base station installation
and service instructions
Installing the boiler
Electrical connections
(cont.)
5773 216 GB
Installation
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...