146
Checking the fuse
F1
A
1.
Switch off the power.
2.
Release the side closures and pivot
the control unit down.
3.
Remove cover
A
.
4.
Check fuse F1 (see connection and
wiring diagram).
Extension kit for heating circuit with mixer
Checking the setting of rotary selec-
tor S1
The rotary selector on the PCB of the
extension kit defines the assignment to
the relevant heating circuit.
Heating circuit
Rotary se-
lector S1 set-
ting
Heating circuit with mix-
er M2
(heating circuit 2)
2
2 3 4
5
6
10
9 8 7
Heating circuit with mix-
er M3
(heating circuit 3)
4
4
2 3
5
6
10
9 8 7
Troubleshooting
Repair
(cont.)
5773 216 GB
Содержание Vitodens 222-F B2TA series