130
Dis-
played
fault
code
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
E1
X
X
Burner in a fault
state
Ionisation
current too
high during
calibration
Check gap be-
tween ionisation
electrode and
burner gauze as-
sembly (see
page 52).
In open flue opera-
tion, prevent high
incidence of dust in
the combustion
air.
Press reset button
R
E3
X
X
Burner in a fault
state
Heat transfer
too low during
calibration.
Temperature
limiter has
shut down
Ensure adequate
heat transfer.
Press reset button
R
E4
X
X
Burner blocked Fault, 24 V
supply volt-
age
Replace control
unit
E5
X
X
Burner blocked Fault, flame
amplifier
Replace control
unit
E6
X
X
Burner blocked System pres-
sure too low
Top up with water
Troubleshooting
Fault codes
(cont.)