![Viessmann Vitodens 222-F B2TA series Скачать руководство пользователя страница 136](http://html1.mh-extra.com/html/viessmann/vitodens-222-f-b2ta-series/vitodens-222-f-b2ta-series_installation-and-service-instructions-manual_1017277136.webp)
136
Dis-
played
fault
code
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
Fd
X
X
Burner in a fault
state
Fault, burner
control unit
Check ignition
electrodes and
connecting cables.
Check whether a
strong interference
(EMC) field exists
near the appliance.
Press reset button
R
Replace control
unit if fault persists
FE
X
X
Burner blocked
or in a fault
state
Boiler coding
card or main
PCB faulty, or
incorrect boil-
er coding
card
Press reset button
R
. If the fault per-
sists, check the
boiler coding card
and replace boiler
coding card or con-
trol unit if necessa-
ry
FF
X
X
Burner blocked
or in a fault
state
Internal fault
or reset but-
ton
R
blocked
Start the appliance
again. Replace the
control unit if the
appliance will not
restart
Note
In the case of subscriber faults, "Sub-
scriber fault ..." is displayed.
Troubleshooting
Fault codes
(cont.)
5773 216 GB
Содержание Vitodens 222-F B2TA series
Страница 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Страница 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Страница 19: ...19 2x 4x 4 3 5 2 1 Installing the boiler Opening the control unit casing 5773 216 GB Installation...
Страница 29: ...29 5 4 2 6 2x 3 1 Installing the boiler Closing the control unit casing 5773 216 GB Installation...
Страница 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Страница 194: ...194 5773 216 GB...
Страница 195: ...195 5773 216 GB...