Function code
group
Function
description
Illustrate
P0
~
PF
Basic function
parameter group
Compatible with KD600 series function codes
A0
~
A3
Second motor
parameter group
The second motor parameters, acceleration and
deceleration time, control mode, etc. can be set
independently
B0
~
B6
Enhanced function
parameter group
System parameter setting, user function code
customization, optimization control, AI/AO
correction, master-slave control, brake function
and sleep function;
C0
~
CF
Special plane function
selection group
Choose to use different professional inverter
functions;
U0
~
U1
Monitoring parameter
group
U0 is the fault record parameter group, and U1 is
the user monitoring parameter, which is
convenient to check the relevant output status;
4.2 Organization of Inverter Function Codes
Chapter 4 Operation and Display
-50-
4.3 Function code viewing and modification method description
AC drives adopts three-level menu structure for parameter setting and other oper-
ations. The three-level menus respectively are: functional parameter group( first-
level menu)
→
function code ( second- level menu)-function code setting value
(third-level menu). Operational process is shown in Figure 4-2:
Figure 4-2
Three-level menu operation flow chart
50
.
00
P0
PF
A0
A3
B0
B6
U0
PRG
U1
P0
-
00
P0
-
06
0
5
P0
-
07
Level I menu (function code group number selection)
Level I menu (function code group number selection)
When A0-00=1, groups A1~A3 are invisible
When A0-00=2, groups A1~A3 are visible
Cycle in sequence when pressing the UP key
Press DOWN to cycle in reverse order
Status parameter page
(default parameter)
Toggle
PRG
Return
ENTER
Enter
When pressing the UP key (+), the function code serial number decreases by one
Press the DOWN key (-) to add one to the function code serial number
ENTER
Enter
PRG
Return
ENTER
Save
UP/DOWN key to modify
ENTER
Enter
Next function
code serial number
Level II menu
(Function code serial
number selection)
Level III menu
(function code value setting)
C
h
a
p
te
r
4
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...