Chapter 4 Operation and Display
-56-
Confirm the parameters through the verification function,
and save them if they are correct.
At this point, the preparations before running are completed
Perform optimal adjustment and individual parameter setting
(P0-04: running command source, P0-06: main frequency source,
P0-10: frequency source selection)
Figure 4-5
Basic steps before running
Sub-flowchart A-1 (motor running in open-loop vector control mode)
Sub-flowchart A-1 describes the start-up procedure for open-loop vector (velocity
-less vector) control. Vector control is effective in applications requiring high start-
ing torque, torque limitation, etc.
YES
YES
NO
NO
NO
YES
Self-flow
diagram A
Can the load be
disconnected for motor
self-learning?
Is the load of the
motor below 30% of
the rated value?
Does the motor test
report have data marked with
the applicable motor?
Static tuning
(F4-00=1)
Rotary tuning
(F4-00=2)
Manually set
motor parameters
C
h
a
p
te
r
4