-157-
Chapter 6 Description of Function Codes
Value
Function
Description
8
Free parking
The inverter blocks the output, and the motor stopping
process is not controlled by the inverter. It is often used
when there is a large inertia load and there is no
requirement for stopping time.
9
Fault reset (RESET)
External fault reset function. Same function as the
RESET key on the keyboard.
10
Run pause
The inverter decelerates to stop, but all running
parameters are in the memory state. Such as PLC
parameters, swing frequency parameters, PID
parameters. After this signal disappears, the inverter
resumes running to the state before stopping.
11
External fault normally
open input
When the external fault signal is sent to the inverter, the
inverter reports a fault and stops.
12
Multi-speed terminal 1
A total of 16-segment settings can be achieved through
the digital state combination of the four terminals. The
detailed combination is shown in Table 5-2.
13
Multi-speed terminal 2
14
Multi-speed terminal 3
15
Multi-speed terminal 4
16
Acc/ Dec time
selection 1
Four kinds of acceleration and deceleration time settings
can be selected through the combination of the digital
states of the two terminals. The detailed combination is
shown in Table 5-3.
17
Acc/ Dec time
selection 2
18
Frequency source
switchover
The main frequency source X and the switching
frequency source set by P0-10 are switched through this
terminal.
19
UP/DOWN setting clear
(terminal, keyboard)
Use this terminal to clear the frequency value changed
by UP/DOWN and restore the given frequency to the
value set by P0-11.
20
Run command
switchover terminal
When the command source is not the keyboard, the
terminal control and keyboard control can be switched
through this terminal. When it is communication,
communication and keyboard control can be carried out
through this terminal.
21
Acceleration/Deceleratio
n prohibited
Ensure that the inverter is not affected by external
signals (except stop command) and maintain the current
output frequency.
C
h
a
p
te
r
6
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...