Chapter 6 Description of Function Codes
When the inverter starts to run, it starts from the starting frequency. If the given frequency is
lower than the lower limit frequency during the running process, the inverter will always run at
the lower limit frequency until the inverter stops or the given frequency is greater than the lo-
wer limit frequency.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-18
lower frequency
0.00Hz
~
P0-16
0.00Hz
☆
Define the binding combination between 3 running command channels and 9 given frequency
channels to facilitate switching of frequency sources.
0: no binding
1: Digital setting frequency
2: Ai1
3: Ai2
4: Multi-speed
5: Simple PLC
6: PID
7: Communication given
8: PULSE pulse setting (HDI)
Units digit: selection of frequency source bound by operation panel command
Tens place: Terminal command binding frequency source selection
Hundreds place: Communication command binding frequency source selection
Thousands: reserved
The meaning of the above frequency given channel is the same as the main frequency X sel-
ection P0-06, please refer to the description of the function code of P0-06.
Different running command channels can be bundled with the same frequency given channel.
When the command source has a bundled frequency source, the frequency source set by
P0-06~P0-10 will no longer work when the command source is valid.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-19
Command source
binding selection
000
~
888
000
☆
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-20
Frequency Decimal
Selection
1
~
2
2
★
C
h
a
p
te
r
6
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...