Chapter 6 Description of Function Codes
-132-
By changing this function code, the rotation direction of the motor can be changed without
changing any other parameters, which is equivalent to the conversion of the rotation direction
of the motor by adjusting any two lines of the motor (U, V, W). For details.
Tip: After the parameters are initialized, the running direction of the motor will return to the
original state. Use with caution in situations where it is strictly forbidden to change the directi-
on of the motor after the system is debugged.
<
1> is the range of frequency decimal point P0-20=2, when P0-20=1, the range is: 50.0Hz
~
1200.0Hz.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-14
Maximum output
frequency
50.00Hz
~
600.00Hz<1>
50.00Hz
★
This function code is used to define the source of the upper limit frequency.
0: Digital setting P0-16
1: AI1, 100% of the input setting corresponds to P0-14
2: AI2, 100% of the input setting corresponds to P0-14
3: Communication setting, the upper computer is given by the communication method
(refer to Appendix A KD600 MODBUS Communication Protocol for details)
4: PULSE pulse setting, the pulse given ramp can be set by P5-30~P5-34
In order to avoid the "speeding" of material disconnection, the upper limit frequency can be
set by analog quantity. When the inverter runs to the upper limit frequency value, the torque
control is invalid, and the inverter continues to run at the upper limit frequency.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-15
Upper limit frequency
source
0
~
4
0
★
When the upper limit frequency is given by analog or Pulse, this parameter is used as the
offset of the analog. The function is to add the bias frequency to the set value of the analog
upper limit frequency as the set value of the final upper limit frequency.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P0-16
Upper limit frequency
P0-18
~
P0-14
50.00Hz
☆
P0-17
Upper limit frequency offset
0.00Hz
~
P0-14
0.00Hz
☆
C
h
a
p
te
r
6
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...