Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-10
Flux Brake Gain
0
~
200
100
☆
This parameter can suppress the bus voltage rise during the deceleration process of the inv-
erter. The larger the value, the better the suppression effect.
The magnetic flux braking is to increase the motor terminal current by increasing the output
voltage of the inverter, thereby improving the consumption capacity of the feedback energy
and suppressing the rise of the bus voltage. The greater the gain, the greater the motor curr-
ent, so please pay attention in the application. It is recommended to set this value to 0 when
there is a braking resistor at the same time, otherwise an abnormality may occur due to the
large deceleration current during deceleration.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-11
Oscillation suppression gain
0
~
100
Model is
determined
☆
This parameter is used to suppress motor vibration. When the motor oscillates, please incre
-
ase the value appropriately, but try to set it as small as possible when the motor does not os
-
cillate, so as not to have too much influence on the V/F operation. Under normal circumstan
-
ces, no modification is required.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-13
VF slip compensation time
constant
0.02s
~
1.00s
0.30s
☆
This parameter is used to set the slip compensation time constant. Decreasing this value can
enhance the response speed, but the speed fluctuation may increase. Increasing this value
increases speed stability, but reduces responsiveness. Under normal circumstances, no mod-
ification is required.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P2-15
Output voltage source selection
when VF is separated
0
~
7
0
☆
0: Digital setting (P2-14);
1: AI1;
2:
2;
AI
C
h
a
p
te
r
6
-146-
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...