Chapter 6 Description of Function Codes
-212-
Running
direction
Y1 or RELAY output
PC.19
PC.21
PC.00
PC.18
PC.20
PC.23
PC.01
PC.02
PC.14
PC.15
Fig.6-28 Simple PLC schematic diagram
Function
code
Name
Description
(setting range)
Factory
Default
Change
PC-16
PLC operation mode
0~2
0
☆
The simple PLC function has two functions: as a frequency source or as a voltage for VF sep-
aration.
Figure 6-29 is a schematic diagram of a simple PLC as the frequency source. When the sim-
ple PLC is used as the frequency source, the positive and negative values of PC-00~PC-15
determine the running direction. If it is negative, it means that the inverter runs in the opposite
direction.
Running
direction
DO or RELAY output
PC.19
PC.21
PC.18
PC.20
PC.23
PC.01
PC.02
PC.14
PC.15
Fig.6-29 Simple PLC schematic diagram
PC.21