Chapter 4 Operation and Display
-58-
4.6 Start-stop control of inverter
There are 3 sources for the start and stop control commands of the inverter, nam-
ely panel control, terminal control and communication control, which are selected
by function parameter P0-04.
4.6.1 Source selection of start-stop signal
In the stop or running state, various state parameters can be displayed respecti
-
vely through the shift key “
”. The function code P7-29 (running parameter)
and P7-30 (stopping parameter) select the parameter display of this parameter
in the running/stop state according to the binary digits. There are sixteen runn
-
ing/stop state parameters that can be displayed or not. Details For the descripti
-
on, see the parameter description of parameters P7-29 and P7-30 in Chapter 5.
4.5.3 Review of status parameters
SHIFT
P0-04
Run command
source setting
Factory default: 0
Factory default
Predeter
mined
area
0
Operation panel command
channel (LED off)
Press RUN, STOP to start and stop
1
Terminal command
channel (LED on)
The DI terminal needs to be defined
as the start-stop command terminal
2
Communication command
channel (LED flashing)
Adopt MODBUS-RTU protocol
Through the keyboard operation, make the function code P0-04=0, which is the
start-stop control mode of the panel, press the "RUN" key on the keyboard, the
inverter will start running (the RUN indicator light is on); when the inverter is runn-
ing , press the "STOP" key on the keyboard, the inverter will stop running (RUN
indicator light is off).
4.6.1.1 Panel start-stop control
The terminal start-stop control method is suitable for the occasions where the sa-
mpling toggle switch and the electromagnetic switch button are used as the start-
stop of the application system, and it is also suitable for the electrical design of the
controller to control the operation of the inverter with the dry contact signal.
4.6.1.2 Terminal start-stop control
C
h
a
p
te
r
4
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...