Value
Function
Description
10
Frequency limited
When the set frequency exceeds the upper and lower
frequency limits and the output frequency of the inverter
reaches the upper and lower frequency limits, the ON
signal is output.
11
Ready to run
The main circuit and control circuit power supply is
established, the inverter protection function does not act,
the inverter is in a running state, and the ON signal is
output.
12
AI1> AI2
When the value of analog input AI1 is greater than the
other input AI2, output ON signal
.
13
upper limit frequency
reached
When the running frequency reaches the upper limit
frequency P0-16, the ON signal is output
14
Lower limit frequency
reached
When the running frequency reaches the lower limit
frequency P0-18, the ON signal is output
15
Brown-out status
output
When the inverter is under voltage state, it outputs ON
signal
16
Communication
settings
For communication settings, please refer to Appendix A
Communication Protocol
17
Timer output
When the timer can realize the time relay function, when
the valid time of the timer input signal reaches the set
closing and opening time, the timing output function is
valid. It needs to be used in conjunction with No. 25
function of DI input and P7-39 and P7-40.
18
Running in reverse
When the inverter is running in reverse, it outputs ON
signal.
19
Reserved
reserved
20
Set length reached
When the detected actual length exceeds the set length,
the ON signal is output
21
Torque limit
When the torque limit function is used, the stall protection
function will automatically act
22
Current 1 arrives
Please refer to the description of function codes P7-45 and
P7-46.
23
Frequency 1 arrives
Please refer to the description of function codes P7-43 and
P7-44.
24
Module temperature
reached
When the inverter module radiator temperature (P7-32)
reaches the set module temperature reaching value (P7-
69), the ON signal is output
-169-
Chapter 6 Description of Function Codes
C
h
a
p
te
r
6
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...