When the set frequency is within the jump frequency range, the actual operating frequency
will run at the jump frequency boundary closer to the set frequency. By setting the jump freq-
uency, the inverter can avoid the mechanical resonance point of the load. This inverter can
set 2 jump frequency points. If two adjacent jump frequencies are set to the same value, this
function will not work at that frequency.
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-11
Hop Frequency 2
0.00Hz
~
Maximum frequency
0.00Hz
☆
P7-12
Hop Frequency 2 Amplitude
0.00Hz
~
Maximum frequency
0.00Hz
☆
P7-19
P7-11
P7-10
P7-10
P7-12
P7-12
Time
Output
frequency (Hz)
Fig.6-13 Schematic diagram of hopping frequency
Function
code
Name
Description
(setting range)
Factory
Default
Change
P7-15
Forward and reverse dead
time
0.0s
~
3000.0s
0.0s
☆
Fig.6-14 Schematic diagram of forward and reverse dead time
t1
Output frequency (Hz)
Time
(
t
)
Dead-zone
time
Reverse
rotation
C
h
a
p
te
r
6
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...