Motor selection
Parameters
Motor 1
P4-07: Motor 1 no-load current P4-08: Motor 1 stator resistance
P4-09: Motor 1 rotor resistance P4-10: Motor 1 mutual inductance
P4-11: Motor 1 leakage inductance
Motor 2
A1-07 ~ A1-11: Same as above
If the motor cannot be completely disconnected from the load, select 1 (static tun-
ing) for P4-00 (motor 2 is P1-00), and then press the RUN key on the keyboard
panel to start the motor parameter identification operation.
It can be specified by the function code A0-00, or the digital input terminal function
41 can select the current valid motor parameter group. However, when the digital
input terminal function 41 is valid, it is the priority, and the setting of A0-00 is invalid
at this time.
4.8.3 Setting and switching of multiple sets of motor parameters
A0-00=1
A0-00=2
Motor 1
Motor 2
VF control mode,
can drive multiple motors
at the same time
Vector control mode,
cannot drive multiple
motors at the same time
Vector control mode, supports
time-sharing driving of up to 2
motors, and motor parameters
are stored separately
Figure 4-26
Switching of multiple sets of motors
4.9 How to use the DI port of the inverter
The control board comes with 5 DI ports, numbered DI1~DI5. The internal hardw-
are of the DI port is equipped with a 24Vdc power supply for detection. Users only
need to short-circuit the DI port and the COM port to input the DI signal to the
inverter.
C
h
a
p
te
r
4
Chapter 4 Operation and Display
-74-
Содержание 2S-0.4G-B
Страница 6: ...Safety and Attentions Chapter 1 1 1 Safety Matters 6 1 2 Use Considerations 9...
Страница 80: ...Function Parameter Table 5 1 Functional group 78 Chapter 5...
Страница 126: ...Function Parameter Table Chapter 6...
Страница 245: ......
Страница 249: ......
Страница 255: ......
Страница 287: ...216 286 3 Wiring diagram Single Phase 220V Three Phase 380V U V W Ground Wire Chapter 10 Chapter 10 Appendix...
Страница 300: ...Version 1 0 Design date August 26 2022...