54 - 23/May/97
2.2.8.1 Setup for the Number of Steps/Revolution
From DBM 03 version the number of steps/electrical revolution of simulated encoder can be
set via software (see SE commands).
REMARK: the maximum number of pulses per electrical revolution depends on the R/D
resolution. See Tab.2.1.
The width of C marker can be A (360
°
), A/2 (180
°
) or A/4 (90
°
); it must be specified in the
order. This parameter does not depend on the software commands.
Note: to obtain the resolution per mechanical revolution it is necessary to multiply the pole
pairs by the electrical resolution.
Example: if a FAS T motor with 6 pole resolver is used, 1024 pulses per electrical revolution
mean 1024
∗
3 = 3072 pulses per mechanical revolution.