70 - 23/May/97
3.2.16 Command: DR - Digital Reference
Function:
it allows to enable digital (speed or torque) reference. The drive
will consider as reference the number set via VE command and
ignore connector J7 voltage.
Syntax:
command input:
n
address DR <CR>
Address type:
axis
Unit of measure:
-
Range:
-
Default:
digital reference
Password:
yes
(
∗
) addressing:
yes
Opposite to:
AR
See also:
AR
Note: the status can be interrogated via ST command (bit I)