7 - 23/May/97
1.4 Interfaces
Digital
•
Output for simulated encoder (optional)
•
Serial Link RS485(1200-19200 Baud) full-duplex to manage:
- Acceleration limits
- Autophasing
- Control parameters
- Monitoring of internal parameters
- Range of analog interface
- System status
•
Output for Drive OK axis 1, axis 2, axis 3 (TTL compatible)
On-Off (Optoisolated)
•
Drive OK
•
Drive Enable
•
Motor OK
•
Reference Enable
Analog
•
Input velocity (see MR command)
•
Resolver differential input signals
•
Peak current limit input
•
Output tachometer (see ET command)
•
Max current, velocity reference, velocity error outputs (see ES, SO commands)
1.5 Protection
Module
•
Auxiliary voltage out of tolerance
•
BUS BAR overvoltage
•
BUS BAR undervoltage
•
Motor phase grounded
•
Motor overtemperature
•
Module overtemperature
•
IT protection
•
Abnormal resolver signal
•
Short circuit on motor phases
•
Non-coherent three-phase sequence
•
Actual speed versus reference error
Power Supply
•
Overtemperature
•
Recovery unit not OK