92 - 23/May/97
3.3 Protections
3.3.1 Power Supply
Recovery not ok.
Indicated by: LEDs DRVF (drive fault) on all drives, LED DBR FAULT, optoisolated output
DRIVE OK, bit H of the FA string (see FA command).
Set condition: when recovery power transistor or recovery resistor is broken, in short circuit;
when the recovery is active for too much time.
Effect: all drives inhibit torque
Reset condition: if the condition is not present anymore, power off and on monophase
voltage.
Power supply overtemperature.
Indicated by: LEDs DRVF (drive fault) on all drives, LED OVER TEMP, optoisolated output
DRIVE OK, bit I of the FA string (see FA command).
Set condition: when a limit temperature is reached.
Effect: all drives inhibit torque.
Reset condition: if the condition is not present anymore, power off and on monophase
voltage.