90 - 23/May/97
3.2.48 Command: VO - Analog Velocity Offset Automatic Setting
Function:
it allows to automatically adjust the analog velocity offset
Syntax:
command input:
n
address VO <CR>
Address type:
axis
Unit of measure:
-
Range:
0 to 255
Default:
0
Password:
yes
(
∗
) addressing:
no
Opposite to:
-
See also:
OV
REMARKS:
The VO command must be executed with digital Drive Enable off (stopped motor). Before
executing the command it is necessary to check that the external opto input Drive Enable is
enabled and keyboard Drive Enable is off (OF command).
Notes:
If error > 255, "OUT-OF-RANGE" is displayed.