50 - 23/May/97
Example for a double module with axis 4 and axis 5:
FROM KEYBOARD
4 PW91 <CR>
Enter the password for 2nd module (primary axis = 4)
PASSWORD ON
The correct answer is displayed
<CR>
Only for Vickers keyboard.
4 AP <CR>
Allow axis 4 autophasing.
AUTOPHASING IN PROGRESS
AXIS PHASED
5 AP <CR>
Allow axis 5 autophasing.
AUTOPHASING IN PROGRESS
AXIS PHASED
4 SV <CR>
Save module 4 phasing.
•
Repeat the password and autophasing procedures for subsequent modules (if applicable).
•
Make a hardware reset via button on drive or via positive logic on pin 18 of J8 connector.
2.2.4 Wiring Checks
After phasing each axis, it is possible to check the wiring by rotating the motor via its digital
reference.
•
Enable analog Drive Enable and Reference Enable via positive logic.
•
Check that G2 is in position 2-3, for keyboard priority.
•
Send to every axis the ON command (to enable digital Drive Enable) , the VE command
(for CW slow rotation), the VE- command (for CCW slow rotation), the OF command (to
disable the digital Drive Enable).
Example of checking axis 5 rotation:
FROM KEYBOARD
5 ON <CR>
Enable digital Drive Enable for axis 5
O
Drive Enable led will be on
5 VE 50 <CR>
Set CW rotation at 50 rpm
5 VE-50 <CR>
Set CCW rotation at 50 rpm
5 OF <CR>
Disable digital Drive Enable for axis 5
O
Drive Enable led will be off