80 - 23/May/97
3.2.30 Command: ON - On
Function:
it allows to enable the digital Drive Enable for the adressed axis
(see Par. 2.2.2.)
Syntax:
command input:
n
address ON <CR>
Address type:
axis
Unit of measure:
-
Range:
-
Default:
Digital Drive Enable off
Password:
no
(
∗
) addressing:
yes
Opposite to:
OF
See also:
OF
REMARK:
if opto Drive Enable are not enabled, the following message will be displayed: "ERROR:
DRIVE EN. OPEN". If the axis is not phased "AXIS NOT PHASED" will appear. If the jumper G2
is in position 1-2 (closed) the message "NOT POSSIBLE" will appear.
3.2.31 Command: OV - Analog Offset
Function:
it allows to monitor and to set the analog offset of speed/ torque
analog reference.
A fine adjustment of the analog offset can be done with successive
steps by setting and monitoring the OV parameter.
Syntax:
data monitoring:
n
address OV <CR>
data input:
n
address OV n <CR>
Address type:
axis
Unit of measure:
-
Range:
0 to 255
Default:
128
Password:
yes
(
∗
) addressing:
no
Opposite to:
-
See also:
VO