82 - 23/May/97
3.2.34 Command: PW - Password
Function:
it allows the operator to change critical parameters. After executing
PW command, it is possible to enter the status in which such
modification are permitted. If you want to exit from this mode, set
PW
again.
The DBM 03 release allows to change the password.
Syntax:
command input:
n
address PW n <CR>
data input:
n
address PW n <CR>
Address type:
module
Unit of measure:
-
Range:
1 to 255
Default:
PW91
Password:
-
(
∗
) addressing:
yes
Opposite to:
-
See also:
-
Examples:
n
1 PW91 <CR>:
if previously OFF, the answer is "PASSWORD ON"
n
1 PW137 <CR>:
enters a new password. The answer is "NEW PASSWORD IS 137 SAVE? "
n
1 SV <CR>
saves the new passord. Note that all new parameters will be saved, if changed.
n
1 PW137 <CR>: the answer is be "PASSWORD OFF"
CAUTION: Password protected parameters must be set only when the motor is standstill.
3.2.35 Command: RE - A/D REsolution
Function:
it allows to display the resolution of A/D converter
Syntax:
data monitoring:
n
address RE <CR>
Address type:
module
Unit of measure:
bit
Range:
12 (standard) , 14 (optional)
Default:
-
Password:
no
(
∗
) addressing:
no
Opposite to:
-
See also:
-
Example:
n
1 RE <CR>:
it questions module 1 about the resolution of A/D converter. The standard answer is: "12
BIT A/D CONVERTER IS PRESENT".
REMARK: the 14 bit A/D resolution is an option (CG5504 code). We recommend to contact
the Service Centers to restore the 12 bit resolution from the optional 14 bit resolution.