285
OTA ID scanner
The LTE mobile receives signals from multiple base stations that all these signals share the same spectrum and are present at the
same time. Each base station has unique scrambling code assigned to the particular base station and it differentiates its signal from
other base stations in the area.
The ID Scanner shows key parameters such as RSRP (Reference Signal Received Power) and RSRQ (Reference Signal Received
Quality) that predict the downlink coverage quickly. RSRPs from entire cells help to rank between the different cells as input for
handover and cell reselection decisions. RSRQ provides additional information when RSRP is not sufficient to make a reliable
handover or cell reselection decision.
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto
the instrument using the
Save/Load
icons on the side bar.
1
Tap the
Setup
(
)icon on the side bar.
2
Tap to switch
Carrier Auto Search
to
Start
to start searching the SSB frequency and apply it or to
Stop
to stop searching.
NOTE
If searching is unavailable, the instrument displays a pop-up message saying that it fails to detect NR (SSB)
frequency.
3
Tap to switch
Radio Config
and set
Duplex Type
(FDD/TDD),
DSS Type
(Co-channel/
Adjacent channel
), and
Technology
(LTE/NR) and other related parameters as below:
You can select Co-channel to find NR frequency based on the LTE operating frequency in co-channel and select Adjacent
channel to search both LTE and NR frequency. Note that Adjacent channel will be available in the next release.
When
LTE
is selected as
Technology
, do the following steps:
a
Select
Bandwidth
(MHz) from the following choices:
20
,
15
,
10
, or
5
.
b
Select
MIMO
between
2x2
and
4x4
.
c
Select
Cyclic Prefix
between
Normal
and
Extended
.
Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference.
▪
Normal
: Intended to be sufficient for the majority of scenarios
▪
Extended
: Intended for scenarios with particularly high delay spread.
d
Select
PHICH Ng
between
Normal
and
Extended
and then to set the number of PHICH groups (Ng) :
1/6
,
1/2
,
1
, or
2
.
The PHICH group value/Ng is decided based on the number of PHICH groups per subframe. PHICH duration is a higher
layer parameter configured either as Normal or Extended that says the demodulator how many symbols per subframe are
used by PHICH
.
▪
Normal
: There are 8 PHICH sequences in one PHICH group (4 symbols).
▪
Extended
: There are 4 PHICH sequences in one PHICH group (2 symbols).
When
NR
is selected as
Technology
, do the following steps:
a
Select
Sub-Carrier Spacing
as
15 kHz (Case A)
.
The standard for NR SCS is 15 kHz and CellAdvisor 5G supports 15 kHz of sub-carrier spacing.
4
Tap to switch
CFI
to
Manual or Auto
.
▪
Auto
lets the instrument set the number of OFDM symbols used for transmitting PDCCHs in a subframe.
▪
Manual
sets the number of OFDM symbols manually. The set of OFDM symbols that can be used for PDCCH in a
subframe is given by 0, 2, 3 or 4 in 1.4 MHz bandwidth and 1, 2 or 3 in other bandwidths.
5
Tap
CFI
and input a value from 1 to 3 as desired using the on-screen keyboard.
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......