CellAdvisor 5G User's Guide
265
NOTE
Based on the GSCN input frequency, the SSB Frequency is automatically changed.
10
Tap
PCI
(
Physical Cell ID
) and select between
LTE PCI
and
NR PCI
.
a
Tap to switch
LTE PCI
Mode
to
Manual
or
Auto
and input a value from 0 to 503.
The
PCI
switches to
Manual
.
b
Tap
NR
PCI
Mode
to
Manual
or
Auto
and input a value from 0 to 1007.
The
PCI
switches to
Manual
.
NOTE
You can set
Auto to let the instrument detect the Physical Cell ID for the LTE/NR signal automatically and
Manual
to set the specific Physical Cell ID for the LTE/NR signal manually in order to speed up the synchronization with a
BTS.
11
Tap
PDSCH
, and then select the PDSCH modulation type option:
Auto
,
QPSK
,
16 QAM
,
64 QAM
,
256 QAM
,
LTE
E-TM3.3
,
LTE
E-TM3.2
,
LTE
E-TM3
.
1a
,
LTE
E-TM3.1
,
LTE
E-TM2a
,
LTE
E-TM2
,
LTE
E-TM1.2
or
LTE
E-TM1.1
.
If two or more modulation types are used in a frame, select
Auto
. If the PDSCH uses the same modulation type in a frame or in
a subframe, select a specific modulation type to get more accurate EVM.
12
Tap
PDSCH
Threshold
to set the threshold for PDSCH and enter a value by using the on-screen keyboard.
13
Tap
PDSCH Precoding
to set
On
or
Off
to enable or disable the PDSCH precoding.
14
Tap
Menu
>
Display
and select
Reset
to refresh your measurement screen.
Setting limit
1
Tap
Menu
>
Limit
.
2
Tap
NR Limit
and set the limits depending on your selected measurement mode:
To set
the limit
for
Select
Set
Frequency
error
Frequency
error
Test limits On/Off, High Limit/Low Limit
PDSCH for
data error
vector
magnitude
PDSCH
EVM
Test limits On/Off, High Limit (QPSK), High Limit (16QAM), High Limit (64QAM), High Limit (256QAM)
RMS for
data error
vector
magnitude
Data EVM
RMS
Test limits On/Off, High Limit
Peak for
data error
vector
magnitude
Data EVM
Peak
Test limits On/Off, High Limit (QPSK), High Limit (16QAM), High Limit (64QAM), High Limit (256QAM)
Time error
Time Error
Test limits On/Off, High Limit/Low Limit
3
Tap
LTE Limit
and set the limits depending on your selected measurement mode:
To set
the limit
for
Select
Set
Frequency
error
Frequency
error
Test limits On/Off, High Limit/Low Limit
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......