Using 5G NR Signal Analyzer
206
SSB SCS
(kHz)
Sync Raster Resolution
(kHz)
Sync Raster Offset
Range
Sync SCS Resolution
(kHz)
Sync SCS Offset
Range
15
180
0 to 250
15
0 to 11
30
180
0 to 506
30
0 to 5
120
720
0 to 92
120
0 to 5
240
720
0 to 48
240
0 to 2
7
Tap
SSB Center Frequency
and input the value using the on-screen keyboard.
8
Tap
GSCN
and input the value using the on-screen keyboard.
Based on the GSCN input frequency, the SSB frequency changes automatically.
9
Tap
L
to set the maximum number of SS-PBCH blocks within a single SS burst set (A set of SS being transmitted in 5 ms
window of SS transmission) among
4
,
8
and
64
.
Refer to the selection criteria based on the table in
Step 5
.
10
Tap
SSB Auto
Search
Mode
and do the following steps:
a
Tap
Auto Preamp/Atten
and switch
SSB Auto Search
to
Start
to set preamp and attenuation automatically.
b
Tap
Manual
and switch
SSB Auto Search
to
Start
for manually setting based on your need.
NOTE
If you tap SSB Auto Search to Start, the searching progress screen appears to let you know the status of searching.
You can tap SSB Auto Search to Stop to stop searching.
11
Tap
SSB Periodicity
and select the options from
5 ms
,
10 ms
,
20 ms
,
40 ms
,
80 ms
,
160 ms
.
The SS burst period (SSB periodicity) is defined by each base station and network configurable. 20 ms is the default for the
initial cell selection.
12
Tap to switch
PCI
(
Physical Cell ID
) to
Manual
or
Auto
.
13
Tap
PCI
and input a value from 0 to 1007 using the on-screen keyboard.
The
PCI
switches to
Manual
.
NOTE:
The instrument does not automatically save the collected data. It is recommended that you save the result.
Otherwise, you will lose all the collected data.
Logging data
1
Follow the
step 1 to 3
in Setting measure setup.
2
Tap the
Start
button (
) on the right panel of the map to start plotting on the map.
When you select a point on the map, a marker appears and the Information window appears on the right panel.
3
Tap the
Stop
(
) button to stop plotting.
4
Tap the
Pause
button (
) to pause plotting, then the
Pause
button changes to (
) and GPS point cannot be
plotted.
5
If you start test and select
Setup
>
Map Config
>
Plot Point
>
Position
, you can undo by tapping the
Start
button.
6
If you select
Stop
button,
Plot Stop
popup window appears.
7
Save the logging file to your USB.
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......