CellAdvisor 5G User's Guide
189
3 to 6 GHz (FR1)
8
A
{2,8} +14*n
15 kHz
5 (1 ms)
B
{4,8,16,20} +28*n
30 kHz
10 (0.5 ms)
C
{2,8} +14*n
30 kHz
10 (0.5 ms)
> 6 GHz (FR2)
64
D
{4,8,16,20} +28*n
120 kHz
40 (0.125 ms)
E
{8,12,16,20,32,36,40,44} +56*n
240 kHz
80 (62.5 ms)
3
Tap
Sync Raster/SCS Offset
to set the sync raster resolution to 180 kHz (FR1) or to 720 kHz (FR2) for carrier frequency center
using the on-screen keyboard.
The following table shows the sync raster offset range and sync SCS offset range per SSB SCS and sync raster/SCS
resolution.
SSB SCS
(kHz)
Sync Raster Resolution
(kHz)
Sync Raster Offset
Range
Sync SCS Resolution
(kHz)
Sync SCS Offset
Range
15
180
0 to 250
15
0 to 11
30
180
0 to 506
30
0 to 5
120
720
0 to 92
120
0 to 5
240
720
0 to 48
240
0 to 2
4
Tap
SSB Frequency
and input the value using the on-screen keyboard.
5
Tap
GSCN
and input the value using the on-screen keyboard.
Based on the GSCN input frequency, the SSB frequency changes automatically.
6
Tap
L
to set the maximum number of SS-PBCH blocks within a single SS burst set (A set of SS being transmitted in 5 ms
window of SS transmission) among
4
,
8
and
64
.
Refer to the selection criteria based on the table in
Step 2
.
7
Tap
SSB Auto
Search
Mode
and do the following steps:
a
Tap
Auto Preamp/Atten
and switch
SSB Auto Search
to
Start
to set preamp and attenuation automatically.
b
Tap
Manual
and switch
SSB Auto Search
to
Start
for manually setting based on your need.
NOTE
If you tap SSB Auto Search to Start, the searching progress screen appears to let you know the status of searching.
You can tap SSB Auto Search to Stop to stop searching.
8
Tap
SSB Periodicity
and select the options from
5 ms
,
10 ms
,
20 ms
,
40 ms
,
80 ms
,
160 ms
.
The SS burst period (SSB periodicity) is defined by each base station and network configurable. 20 ms is the default for the
initial cell selection.
9
Tap to switch
PCI
(
Physical Cell ID
) to
Manual
or
Auto
.
10
Tap
PCI
and input a value from 0 to 1007 using the on-screen keyboard.
The
PCI
switches to
Manual
.
11
Tap
Menu
>
BW/AVG
>
Average
to set the number of measurements to be averaged using the on-screen keyboard.
The input value range is from 1 to 100.
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......