CellAdvisor 5G User's Guide
199
240
720
0 to 48
240
0 to 2
4
Tap
SSB Frequency
and input the value using the on-screen keyboard.
5
Tap
GSCN
and input the value using the on-screen keyboard.
Based on the GSCN input frequency, the SSB frequency changes automatically.
6
Tap
L
to set the maximum number of SS-PBCH blocks within a single SS burst set (A set of SS being transmitted in 5 ms
window of SS transmission) among
4
,
8
and
64
.
Refer to the selection criteria based on the table in
Step 2
.
7
Tap
SSB Auto
Search
Mode
and do the following steps:
a
Tap
Auto Preamp/Atten
and switch
SSB Auto Search
to
Start
to set preamp and attenuation automatically.
b
Tap
Manual
and switch
SSB Auto Search
to
Start
for manually setting based on your need.
NOTE
If you tap SSB Auto Search to Start, the searching progress screen appears to let you know the status of searching.
You can tap SSB Auto Search to Stop to stop searching.
8
Tap
SSB Periodicity
and select the options from
5 ms
,
10 ms
,
20 ms
,
40 ms
,
80 ms
,
160 ms
.
The SS burst period (SSB periodicity) is defined by each base station and network configurable. 20 ms is the default for the
initial cell selection.
9
Tap to switch
PCI
(
Physical Cell ID
) to
Manual
or
Auto
.
10
Tap
PCI
and input a value from 0 to 1007 using the on-screen keyboard.
The
PCI
switches to
Manual
.
11
Tap to switch
Sorting Type
to
PCI
or
RSRP
.
If you select PCI, it shows PCI information on the measurement screen and if you select RSRP, it shows S-SS RSPR power on
the measurement screen. You can also set it in the Detected ID List table.
NOTE:
You can go to
Menu
>
Frequency
>
Center Frequency List
to add frequently used center frequency using the
Add
button in the Frequency List or to delete the selected frequency using the
Delete
button. You can also apply
one of the default frequencies in the Frequency List by tapping the
Apply
button.
Beam analyzer measurement
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......