Section 4: Electrical Connections
Note: Throughout this section, the term APx refers
to the GASGUARD AP series of controllers.
Example: GASGUARD AP10 Controller
All electrical connections must comply with Article 300 - Wiring Methods and Article
500 - Hazardous (Classified) Locations of the National Electric Code (NEC), if
installed in the United States. Reference to the use of this equipment in Hazardous
Locations only applies to installations located within the United States of America.
These systems are not Explosive Atmosphere Directive approved for use in the
European Community by virtue of not being reviewed for compliance.
Range of Environmental Conditions:
•
0 to 60° C Interior Operating Temperature Range (Under Roof)
•
-20 to 60° C Optional Outdoor Temperature Range
•
95% Maximum Relative Humidity
•
2000 Meters Above Sea Level, Maximum
•
100 to 240 VAC Nominal Voltage Range, 50 to 60 Hertz
•
± 10% Fluctuation of Nominal Voltage Range