up in the excess flow switch.
9.6.2 Low Pneumatic Supply Pressure
Probable Cause
Corrective Action
Pneumatic supply to the controller is
less than 65 psig (4.5 barg).
Adjust pneumatic pressure to the
controller to 85-95 psig (5.9-6.6 barg).