Chapter 8 - Operating Procedures
_______________________________________________________________________________________________________________
MNL000536
Revision 1
03/26/2018
BSGS eV / BULKGUARD eV
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
8
-
19
Note: A subroutine will perform the Vacuum
Leak Test (Cylinder Leak Test) to insure the
source container valve is closed.
The leak test status is displayed in the status
box in the bottom left corner.
Note: During the leak test the status box
displays the following:
1)
The leak test being run.
2)
The process line number.
Source A1 = process line 1,
Source A2 = process line 2
Source B1 = process line 3
Source B2 = process line 4
3)
The time remaining until the completion of
the leak test.
(1) (2) (3)
Note: Upon successful completion of the leak
test, a purge/vent subroutine is run to purge out
the pigtail.
During the cycle purge, status is displayed in the
status box in the bottom left corner.
Note: During the cycle purge the status box
displays the following:
1)
The cycle purge being run.
2)
The process line number.
3)
The number of times the cycle has been run,
compared to the number of times the cycle
is configured to be run.
(1) (2) (3)