Chapter 3 - Module Specifications
_______________________________________________________________________________________________________________
MNL000531
Revision 1
03/26/2018
BSGS eV / BULKGUARD eV
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
3
-
6
Electrical Requirements
± 10% Fluctuation of Nominal Voltage Range
Short Circuit Current Rating (SCCR) is 10 kA for controller power feed, 5 kA for single power
feed or heater power feed
Single Power Feed for Module – with JT Heater:
208 – 240 VAC - 50/60 HZ
Full load current - 32 amps
5 kAIC @ 240 VAC, 75 deg. C terminal rating
Single Power Feed for Module – with Heat Trace, no JT Heater:
208 – 240 VAC - 50/60 HZ
Full load current - 7 amps
5 kAIC @ 240 VAC, 75 deg. C terminal rating
Single Power Feed for Module – AP11 only, no Heaters:
100 – 240 VAC - 50/60 HZ
Full load current - 4 amps
10 kAIC @ 240 VAC, 75 deg. C terminal rating
Dual Power Feed – Critical Power to AP11 Controller, Normal Power to JT Heater/Heat Trace
AP11 Controller:
100-240 VAC - 50/60 HZ
Full load current - 4 A
10 KAIC @ 240 VAC, 75 deg. C terminal rating
JT Heater (with or without Heat Trace):
208-240 VAC - 50/60 HZ
Full load current - 32 A
5 kAIC @ 240 VAC, 75 deg. C terminal rating
Heat Trace only (no JT Heater):
208-240 VAC - Single phase, 50/60 HZ
Full load current - 7 A
5 kAIC @ 240 VAC, 75 deg. C terminal rating