Chapter 8 - Operating Procedures
_______________________________________________________________________________________________________________
MNL000536
Revision 1
03/26/2018
BSGS eV / BULKGUARD eV
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
8
-
21
4.B Change Source Container
Purpose
: This semi-automated Sub-Section describes the AP11 Controller Program Routine that is
used to change a source container. Note that the sources are being referred to generically with ‘x’
meaning which side the component is installed and ‘y’ meaning which source on that side. MV1-B2
would be the second source container on the B side of the equipment.
If the system is in the cross-purge configuration and there are two sources installed on one process
side, the Change Cyl mode will impact both sources (A1 and A2, B1 and B2) when initiated on one
side of the system. There is no isolation that allows this mode to be run only on one source at a time
without halting flow from the other source.
The following table describes the steps to be followed when using the Change Cylinder routine.
1.
Verify that “Pre-Purge Completed” is displayed
in the controller mode box.
2.
Touch anywhere on the graphics portion of the
screen. Display will show a request for password
input.
3.
PASSWORD WINDOW
Enter password on keypad and press the “OK”
key.