Baud Rate:
used in CANopen communication. Regardless of the selected bitrate, the bit sample
timing is set as close as possible to 87.5 % according to the CANopen specification.
Operate Mode:
is used to change the modes of operation between standardized profile modes and
VACON
®
specific Bypass mode.
Different operate modes activate different device profile segment objects. Accessing e.g. CiA-402
velocity profile objects in Bypass mode is not possible. See Chapter 8.2 Velocity mode and Chapter
8.3 Bypass mode.
Comm. Timeout:
Fieldbus communication timeout is time in seconds after a fault is created from
CAN bus communication errors (PASSIVE, BUS-OFF). Setting this value to 0 disables CAN bus er-
rors from triggering a fault in AC drive. This does not affect other CANopen faults, e.g. heartbeat
consumer times. This value is the same as object 0x2004 - Communication timeout. See conditions
when fieldbus communication timeout is activated in Chapter 9.2 Fieldbus timeout fault (F53).
Mode:
compatibility mode(s) can be activated using this parameter. This parameter is the same as
object 0x2005 - Mode.
7.1.1
OPTE6 additional panel parameters
From VACON
®
100 (INDUSTRIAL V027 and FLOW V018) and OPTE6 V009 firmware version forwards,
CANopen bus communication parameters are stored and can also be modified directly from panel
parameters. The stored parameters are modifiable and stored under the "Parameters" menu and
these parameters are restored after power cycle. The active settings are visible under the "Monitor"
menu.
These parameters are separated into sub-folders for easier modification. It is recommended to use
VACON
®
Live PC-tool to modify the parameters.
General Heartbeat RPDO1 Communication RPDO2 Communication
2
Bypass
VACON
®
specific bypass mode active
3
Puller*
CiA-420 EUROMAP profile, puller mode
active
4
Co-Extruder*
CiA-420 EUROMAP profile, co-extruder
mode active
Table 56. OPTE6 Mode settings
Value
Description
Details
0
Normal
1
Pre V008
Anyparameter service behaves same
as version 7 and earlier in VACON
®
100 family devices. See Chapter 8.5 for
more details.
Table 55. OPTE6 Operate Mode settings
Value
Name
Description