10
vacon • 92
Appendix A: Object dictionary
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
1401
Receive PDO Communiction
Parameter 2
Record
PDO_COMM_PAR
000
Number of Entries
UNSIGNED8
RO
No
0x05
001
COB-ID
UNSIGNED32
RW
No
0x80000300
002
Transmission Type
UNSIGNED8
RW
No
0xFE
003
Inhibit Time
UNSIGNED16
RW
No
0x0
100 μs
005
Event Timer
UNSIGNED16
RW
No
0x0
ms
Object 1402h: Receive PDO Communication Parameter 3
1402
Receive PDO Communiction
Parameter 3
Record
PDO_COMM_PAR
000
Number of Entries
UNSIGNED8
RO
No
0x05
001
COB-ID
UNSIGNED32
RW
No
0x80000400
002
Transmission Type
UNSIGNED8
RW
No
0xFE
003
Inhibit Time
UNSIGNED16
RW
No
0x0
100 μs
005
Event Timer
UNSIGNED16
RW
No
0x0
ms
Object 1600h: Receive PDO Mapping Parameter 1
1600
Receive PDO Mapping Param-
eter 1
Record
PDO_MAPPING
000
Number of Entries
UNSIGNED8
RW
No
0x02
001
Mapping Entry 1
UNSIGNED32
RW
No
0x60400010
002
Mapping Entry 2
UNSIGNED32
RW
No
0x60420010
003
Mapping Entry 3
UNSIGNED32
RW
No
0x00000000
004
Mapping Entry 4
UNSIGNED32
RW
No
0x00000000
Object 1601h: Receive PDO Mapping Parameter 2
1601
Receive PDO Mapping Param-
eter 2
Record
PDO_MAPPING
000
Number of Entries
UNSIGNED8
RW
No
0x04
001
Mapping Entry 1
UNSIGNED32
RW
No
0x20000410
002
Mapping Entry 2
UNSIGNED32
RW
No
0x20000510
003
Mapping Entry 3
UNSIGNED32
RW
No
0x20000610
004
Mapping Entry 4
UNSIGNED32
RW
No
0x20000710
Object 1602h: Receive PDO Mapping Parameter 3
1602
Receive PDO Mapping Param-
eter 3
Record
PDO_MAPPING
000
Number of Entries
UNSIGNED8
RW
No
0x04
001
Mapping Entry 1
UNSIGNED32
RW
No
0x20000810
002
Mapping Entry 2
UNSIGNED32
RW
No
0x20000910
003
Mapping Entry 3
UNSIGNED32
RW
No
0x20000A10
004
Mapping Entry 4
UNSIGNED32
RW
No
0x20000B10
Object 1800h: Transmit PDO Communication Parameter 1
Index
Sub-
index
Description
Object
Code
Data Type
Access
PDO
Mapping
Default
value
Unit
Содержание CANopen OPTE6
Страница 1: ...vacon ac drives canopen option board opte6 user manual ...
Страница 2: ......