CANopen option board interface
vacon • 71
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
8
Range: 0... 4294967296
Range: 0... 65536
8.2.2.8
0X6049 - vl Velocity Deceleration
This object indicates the configured delta speed and delta time of the slope of the deceleration
ramp.
Range: 0... 4294967296
Range: 0... 65536
8.2.3
PDO configuration
This chapter describes the default PDO mapping configuration when using CiA-402 velocity mode.
By default, RPDO/TPDO 2 & 3 are disabled. These settings are restored when:
• changing the operate mode to "Velocity" from either panel or object 0x6060
• using the "Restore from Set" panel parameter when Velocity operate mode is selected, or
• loading a default parameter set with object 0x1011, 1 "Restore all Default parameters"
When the parameter set is restored, the COB-IDs are calculated according to used Node ID.
0x6048.02: Delta time
16
0
Time (in seconds) in which the rpm of the motor will accelerate the amount specified in Delta Speed.
0x6049.01: Delta speed
31
0
Maximum change of rpm the motor will accelerate during the time specified in Delta Time.
0x6049.02: Delta time
16
0
Time (in seconds) in which the rpm of the motor will accelerate the amount specified in Delta Speed.
Table 68. Overview of Receive PDO configuration in CiA-402 vl mode
Object
COB-ID
Size
DATA0
DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7
RPDO1
0x200 +
Node ID
4
0x6040,
Controlword
0x6042,
vl Target Velocity
Not used
RPDO2
0x80000300
+ Node ID
8
0x2000,4
FB PD in 1
0x2000,5
FB PD in 2
0x2000,6
FB PD in 3
0x2000,7
FB PD in 4
RPDO3
0x80000400
+ Node ID
8
0x2000,8
FB PD in 5
0x2000,9
FB PD in 6
0x2000,A
FB PD in 7
0x2000,B
FB PD in 8