5
vacon • 30
OPTE6 layout and connections
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
5.
OPTE6
LAYOUT
AND
CONNECTIONS
5.1
Layout and connections
OPTE6 has two different hardware revisions with slightly different layout. Layout is different in LED
arrangement and termination resistor orientation.
The two hardware revisions are marked with different product codes, and this product code can be
located from the sticker on the top side (location marked in Figure 6).
The two hardware revisions are named 70CVB01605 and 70CVB01124.
Figure 6. OPTE6 board layout
1 = CAN GND (isolated digital ground reference)
2 = CAN L
3 = SHIELD (shield connector)
4 = CAN H
5 = NC (No connection)
6 = Grounding option jumper
7= Bus termination resistor
Figure 7. CAN connector
M/N A N/M