4.6 Main menu
4-14
4.6 Main menu
To enter the main menu press "Menu"
button on the front panel (Figure 2.1, position 6).
Each line of the menu is the touch button. For quick access to the menu item press the
appropriate line by your finger. Navigating in the menu is also made by rotation of encoder
knob, the selection of menu item is made by pressing the encoder knob. To cancel and exit
from the menu repeatedly press the "Menu" button or select "Exit".
If within 30 seconds no pressing or turning the encoder was detected, exit from the menu to the
previous menu and then to the main screen window is made automatically.
Table 4.3. Main menu parameters
Parameter
Function
Description
Ventilation modes
Parameter calls menu of ventilation mode setting.
it. 4.7
Ventilation
parameters
Parameter calls the menu of general ventilation parameters
setting and selection of patient’s type.
it. 4.8
Trigger type
Parameter allows to set type of the inspiration trigger -
pressure or flow one.
it. 4.9
Trig.window
Parameter allows to set the duration of the trigger window
in percent or seconds. Selecting the units of the trigger
window - in percent or in seconds.
---
FiO
2
sensor
autocalibr.
Parameter provides the possibility to measure FiO
2
accurately at changing of external conditions.
it. 4.10
Additional functions Parameter calls the additional functions menu.
it. 4.11
Display settings
Parameter calls menu of settings of graphs and measured
parameters rectangles.
it. 4.12
Trends
Parameter calls the menu of viewing trends and alarm log.
it. 4.13
Alarms
Parameter calls the menu of alarm thresholds setting.
it. 4.14
Sound volume
Parameter calls the menu of setting the volume of alarms
and spontaneous breath signal.
it. 4.15
Service menu
Technical menu for the service personnel.
it. 4.16
Exit
Return to the main window.
---
Содержание MV200
Страница 2: ......
Страница 8: ......
Страница 25: ...2 3 Front panel 2 9 2 3 Front panel Figure 2 1 Front view of the electronic unit ...
Страница 124: ...4 21 Open valve function 4 76 For your notes ...
Страница 158: ...6 11 Check and calibration of mainstream CO2 sensor 6 8 For your notes ...
Страница 160: ...7 Troubleshooting 7 2 For your notes ...
Страница 162: ...8 Transportation 9 Storage 10 Disposal 10 2 For your notes ...
Страница 166: ...13 commission date mark 12 2 For your notes ...
Страница 168: ...14 Maintenance and repair data 14 2 For your notes ...
Страница 196: ...Appendix 2 9 Ideal body weight of the patient IBW App 2 10 For your notes ...
Страница 200: ...Appendix 3 Electromagnetic environment App 3 4 For your notes ...
Страница 201: ...Appendix 4 Pneumatic scheme of ventilator App 4 1 APPENDIX 4 PNEUMATIC SCHEME OF VENTILATOR ...
Страница 202: ...Appendix 4 Pneumatic scheme of ventilator App 4 2 For your notes ...