GLOSSARY
Gl-2
CAPN MS
Mainstream capnometer (service menu message).
CAPNO
Symbol of CO
2
measurement (capnography)
Capnogram
Graphical representation of the instantaneous carbon dioxide concentration.
Cardiac output according
to Fick equation
See CO.
Ccirc
Compliance of the breathing circuit, measured at the short internal test.
CIND
Indication controller. Part of the device’s hardware and software responsible
for displaying and parameterization.
CIVL
Ventilation controller. Part of the device’s hardware and software responsible
for patient’s ventilation.
CMS
1) Centralized monitoring system.
2) Naming of the network card in the service menu.
CMV/PCV
Controlled Mandatory Ventilation / Pressure Control Ventilation.
Controlled mandatory ventilation with pressure control. In this mode inspiration
is provided at with the set pressure, respiratory rate and inspiratory time.
The pressure value is set by Pi parameter delivered above PEEP and firmly
guaranteed during inspiration.
CMV/VCV
Controlled Mandatory Ventilation / Volume Control Ventilation.
Controlled mandatory ventilation with volume control. In this mode the patient
receives the set tidal volume. The shape of the flow curve is rectangular or de-
creasing, at the physician's choice.
CO
Cardiac output according to Fick equation. Indirect method of assessing cardiac
output by oxygen consumption estimation.
Compl. meas.period
Compliance measurement period. Defines the time between the cycles of com-
pliance and resistance measurements.
Compliance
See C
Compliance of the
breathing circuit
See Ccirc
CPAP+PS
Constant Positive Airway Pressure. The ventilation mode supporting spontane-
ous breathing with the set positive airway pressure. The device supports the
spontaneous inspiration attempt with pressure (PS). The criterion for starting
the inspiration support cycle is the inspiratory trigger (flow or pressure).
Cst
Static compliance. Indicator of lungs compliance. Measured by creating a
pause on inspiration (inspiratory pause).
E
Elastance (elasticity of respiratory ways). Reverse value of static compliance.
Measured in mmH
2
O, in CMV, SIMV, PCV-VG modes.
Elasticity of respiratory
ways (elastance)
See
Е
Elimination of
СО
2
per
minute
The difference between the CO
2
concentration of in the exhaled and inhaled
mixture.
ETC
Endotracheal tube compensation. Ventilation parameter.
EtCO
2
Concentration (partial pressure) of
СО
2
in the exhaled mixture.
ETS
Expiration trigger sensitivity. Ventilation parameter.
ExpEndFlow
Flow at the end of expiration (residual gas flow from lungs caused by the in-
com-pleteness of expiration), lpm. Displayed in RESP 2 window.
Expiration trigger sensi-
tivity (ETS)
Expiration trigger sensitivity - percentage of peak inspiratory flow at which the
device switches from inspiration to expiration in the respiratory cycle with pres-
sure support.
Expiratory time constant
See
τ
exp
Содержание MV200
Страница 2: ......
Страница 8: ......
Страница 25: ...2 3 Front panel 2 9 2 3 Front panel Figure 2 1 Front view of the electronic unit ...
Страница 124: ...4 21 Open valve function 4 76 For your notes ...
Страница 158: ...6 11 Check and calibration of mainstream CO2 sensor 6 8 For your notes ...
Страница 160: ...7 Troubleshooting 7 2 For your notes ...
Страница 162: ...8 Transportation 9 Storage 10 Disposal 10 2 For your notes ...
Страница 166: ...13 commission date mark 12 2 For your notes ...
Страница 168: ...14 Maintenance and repair data 14 2 For your notes ...
Страница 196: ...Appendix 2 9 Ideal body weight of the patient IBW App 2 10 For your notes ...
Страница 200: ...Appendix 3 Electromagnetic environment App 3 4 For your notes ...
Страница 201: ...Appendix 4 Pneumatic scheme of ventilator App 4 1 APPENDIX 4 PNEUMATIC SCHEME OF VENTILATOR ...
Страница 202: ...Appendix 4 Pneumatic scheme of ventilator App 4 2 For your notes ...