Page
D-23
MAINTENANCE
Document 57.0003.4200 - 03/2005
Handler with telescopic boom
Agrilift 625 - Telelift 2506
■
Fuse box relays
Ref.
Circuit
K01
Starting enabling command
K02
Forward speed enabling command
K03
Inhibition with brake pedal stepped down
K04
Overload warning system control unit
enabling command
K05
Reverse speed enabling command
K06
Overload warning system solenoid valve
enabling command
ATTENTION
•
Do not use fuses having a higher amperage
than that recommended, since they can
damage the electric system seriously.
•
If the fuse blows after a short time, look for the
fault source by checking the electric system.
•
Always keep some spare fuses for an
emergency.
•
Never try to repair or short blown fuses.
•
Make sure the contacts of fuses and fuse-
sockets ensure a good electric connection and
are not oxidised.
■
Engine compartment fuses and relays
F31
Ref.
Circuit
Amp
.
F30
Preheating control unit maxifuse
50
F31
System protection fuse
50
K11
Start relay
A02
Preheating control unit
K01
K02
K03
K04
K06
K05
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F29
F29
F29
INT
K11
F30
A02