66
Running Your Library
For step-by-step procedures, see the library’s online Help. To access the online Help system, click the
Help
icon at the top right of the web client or operator panel user interface.
Manually Cleaning Tape Drives
The
Clean Drive
screens on the operator panel user interface allow administrative users to manually clean
tape drives.
The
Clean Drive
screens allow you to select the tape drive that you want to clean. You are then prompted
to insert a cleaning cartridge in the topmost I/E station slot and select
Apply
. The library then takes the
associated partition offline, moves the cleaning cartridge from the I/E station slot to the designated tape
drive, and cleans the tape drive.
When the operation is complete, the library moves the cleaning cartridge back to the I/E station slot and
takes the partition back online.
Manually cleaning tape drives can be performed only from the operator panel. The path to open the
appropriate screen is as follows:
•
From the operator panel, select
Tools > Drive Mgmt > Clean Drive
.
Locking and Unlocking the I/E Stations
Each 5U control module and 9U expansion module has an I/E station door with multiple open and close
sensors. A secondary door located behind the I/E station door acts as a redundant indicator as to whether
the I/E station is opened or closed. When you are finished accessing the I/E station, make sure the station
door is fully closed.
Administrative users can use this operation to lock or unlock the doors for all I/E stations that are configured
as I/E station slots. If all I/E station slots are configured as storage, this operation unlocks the control module
I/E station only.
There are three reasons the I/E station door locks:
•
The library imports or exports a cartridge from the I/E station door.
While the library is attempting to import or export a tape from a given I/E station slot, only the
associated I/E station door is locked in the closed position. All other I/E station doors remain
accessible. On a get from an I/E station slot, the associated I/E station door remains locked until
the media has been successfully moved to its destination. This allows the media to be returned to
the I/E station slot in the event of a put error.
Note
Be sure to unload the tape drive before attempting to clean it. If the tape drive is
loaded with a cartridge, it will not available for this operation.
Note
If your library has zero I/E station slots, you will not be able to manually clean
tape drives. See
Configuring I/E Station Slots
on page 40.
Note
Some host applications use a command to lock and unlock I/E station doors.
This command usually cannot be overridden by the library. Use the host
application to lock or unlock I/E station doors if this occurs. Using the library
lock/unlock operation may affect the host application. See your host application
documentation for information.
Содержание Storage Library T128
Страница 1: ...USER S GUIDE 433568 01 ...
Страница 8: ...viii Contents ...
Страница 10: ...x Tables ...
Страница 12: ...xii Figures ...
Страница 28: ...16 Description ...
Страница 34: ...22 Understanding the User Interface Figure 8 Operator Panel User Interface Figure 9 Web Client User Interface ...
Страница 40: ...28 Understanding the User Interface ...
Страница 80: ...68 Running Your Library ...
Страница 84: ...72 Getting Information ...
Страница 138: ...126 Installing Removing and Replacing ...
Страница 164: ...152 Installing Removing and Replacing ...
Страница 174: ...162 Troubleshooting ...
Страница 178: ...166 Working With Cartridges and Barcodes ...
Страница 184: ...172 Specifications ...
Страница 192: ...180 Glossary ...