Y-8
Y-8
Operation Check (Crane Operation)
77
WY05-5030E
10. AML indicator
(O/R mounting/dismounting)
11. AML indicator
(boom mounting/dismounting)
△
1
345-807-15000
Main switch : ON
PTO
: ON
Counterweight : 0 t
Boom angle : 20° - 40°
Boom
: Over-rear
(Slewing angle :180°)
Outrigger extension width: 8.2 m (26.9 ft)
Disconnect the joint connector (CN1212)
from telescoping cylinder.
Check that only warning code W0105 is
displayed (on AML display).
Connect the joint connector (CN1212) to
telescoping cylinder.
Check that warning code W0105 is not
displayed (on AML display).
Press the button of user on the
AML display, with above crane
condition.
Select the maintenance
telescoping Icon (on AML display).
Operate telescoping cylinder to extension
side, move telescoping cylinder to the
TELE.1 boom section.
Main switch: ON
PTO: ON
Disconnect the joint connector (front:
CN1528, rear: CN1529) from outrigger
wiring.
Check that only warning code W0284 is
displayed (on AML display).
Connect the joint connector (front:
CN1528, rear: CN1529) of outrigger
wiring.
Check that warning code W0284 is not
displayed (on AML display).