Y-5
Y-5
Adjusting Procedure (Electric)
39
WY04-2421E
Y-5 Adjusting Procedure
(Electric)
1. B-pin, C-pin detection switch
(CNC1 to C8)
(1) C-pin lock detection switch 1 (CNC1)
(For reference) Dimension E: 5.5 mm (0.22 in)
Move the switch closer to the target by
1.5
+0.5
–
0
mm (0.06
+0.02
–
0
in) from the position where
the switch is ON in the state that C-pin cylinder is
fully retracted.
(2) C-pin unlock detection switch 3 (CNC3)
(For reference) Dimension F: 4 mm (0.16 in)
Move the switch closer to the target by 3
+0.5
–
0
mm
(0.12
+0.02
–
0
in) from the position where the switch is
ON in the state that C-pin cylinder is fully
extended at 10 MPa (102 kgf/cm
2
) (1450 psi)
loading.
(3) B-pin lock detection switch (left) (CNC5),
switch (right) (CNC6)
(For reference) Dimension E: 5.5 mm (0.22 in)
Move the switch closer to the target by
1.5
+0.5
–
0
mm (0.06
+0.02
–
0
in) from the position where
the switch is ON in the state that B-pin cylinder is
fully retracted.
(4) B-pin unlock detection switch (left) (CNC7),
switch (right) (CNC8)
(For reference) Dimension E: 5.5 mm (0.22 in)
Move the switch closer to the target by
1.5
+0.5
–
0
mm (0.06
+0.02
–
0
in) from the position where
the switch is ON in the state that B-pin cylinder is
fully extended.
△
2
344-312-50000
Содержание GR-1600XL
Страница 1: ......
Страница 8: ...7 WA04 5330E 6 Group index System Diagrams Data Adjustment and Checks Y Z Y Z ...
Страница 28: ...14 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 30: ...16 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...
Страница 33: ...19 WY02 2020E Y 2 Y 2 Adjusting Pressure Hydraulic Pressure ...